3、配置command
[root@localhost libexec]# vim /usr/local/nagios/etc/objects/commands.cfg
#检查存储设备
define command {
command_name check_storage
command_line $USER1$/check_openmanage -H $HOSTADDRESS$ --only storage -p -s -b ctrl_fw=0
}
#检查cpu
define command {
command_name check_cpu
command_line $USER1$/check_openmanage -H $HOSTADDRESS$ --only cpu -p -s -b ctrl_fw=0
}
#检查内存
define command {
command_name check_memory
command_line $USER1$/check_openmanage -H $HOSTADDRESS$ --only memory -p -s -b ctrl_fw=0
}
#检查电源
define command {
command_name check_power
command_line $USER1$/check_openmanage -H $HOSTADDRESS$ --only power -p -s -b ctrl_fw=0
}
#检查温度
define command {
command_name check_temp
command_line $USER1$/check_openmanage -H $HOSTADDRESS$ --only temp -p -s -w $ARG1$ -c $ARG2$ -b ctrl_fw=0
}
--only是指只监控某一项,-p是进行画图,-s是状态描述,-b是黑名单,由于我们的服务器固件版本低,为不影响其他监控项在此我们将其加入黑名单将其剔除。
4、配置监控服务
define service{
use local-service
host_name usvr-131,usvr-119,usvr-70,usvr-71,usvr-72,usvr-73,usvr-82,usvr-83,usvr-84,usvr-85,usvr-86,usvr-87
service_description omsa_storage
check_command check_storage
service_groups dell-openmanage
notifications_enabled 1
}
define service{
use local-service
host_name usvr-131,usvr-119,usvr-70,usvr-71,usvr-72,usvr-73,usvr-82,usvr-83,usvr-84,usvr-85,usvr-86,usvr-87
service_description omsa_cpu
check_command check_cpu
service_groups dell-openmanage
notifications_enabled 1
}
define service{
use local-service
host_name usvr-131,usvr-119,usvr-70,usvr-71,usvr-72,usvr-73,usvr-82,usvr-83,usvr-84,usvr-85,usvr-86,usvr-87
service_description omsa_memory
check_command check_memory
service_groups dell-openmanage
notifications_enabled 1
}
define service{
use local-service
host_name usvr-131,usvr-119,usvr-70,usvr-71,usvr-72,usvr-73,usvr-82,usvr-83,usvr-84,usvr-85,usvr-86,usvr-87
service_description omsa_power
check_command check_power
service_groups dell-openmanage
notifications_enabled 1
}
define service{
use local-service
host_name usvr-131,usvr-119,usvr-70,usvr-71,usvr-72,usvr-73,usvr-82,usvr-83,usvr-84,usvr-85,usvr-86,usvr-87
service_description omsa_temp
check_command check_temp!"0=30/15"!"0=40/10"
service_groups dell-openmanage
notifications_enabled 1
}
报错1:
ERROR: You need perl module Net::SNMP to run check_openmanage in SNMP mode
原因:
SNMP监控模式下,check_openmanage 需要 perl-Net-SNMP 支持
解决方案:
安装perl-Net-SNMP包
# yum install -y perl-Net-SNMP
报错2:
ERROR: (SNMP) OpenManage is not installed or is not working correctly
SNMP TABLE ERROR : Requested table is empty or does not exist
原因:
snmp未配置导致。如果先安装snmp,在安装omsa的时候会自动帮你配置好snmp
解决方案:
1、先安装net-snmp,再安装omsa(即srvadmin-all)
or
2、手动配置信息如下:
vim /etc/snmp/snmpd.conf
view all included .1
access notConfigGroup "" any noauth exact all none none
smuxpeer .1.3.6.1.4.1.674.10892.1 一般安装srvadmin的时候会自动加上的
报错3:
SNMP CRITICAL: No response from remote host 'X.X.X.X'
原因:
被监控端没有安装snmp服务
解决方案:
安装snmp服务
# yum install -y net-snmpd
-------------------------------------------------------------------------------
Client:
对Dell服务器的硬件监控需要安装DELL的OMSA,DELL OMSA的全称为Dell Openmanage Server Administrator,它是戴尔公司基于自主研发力量开发的IT系统管理解决方案,
nagios监控Dell linux系统
1、安装snmp服务
[root@BETA6 yum.repos.d]# yum -y install net-snmp net-snmp-devel net-snmp-utils
2、安装dell的yum源
wget -q -O - http://linux.dell.com/repo/hardware/latest/bootstrap.cgi | bash
或者
wget -q -O - http://linux.dell.com/repo/hardware/OMSA_7.2/bootstrap.cgi | bash
注意:只适用rhel系统,CentOS系统无法安装
[root@BETA6 src]# wget -q -O - http://linux.dell.com/repo/hardware/latest/bootstrap.cgi | bash
Cleaning up Everything
Done!
[root@BETA6 src]#
3、安装dell osma
yum -y install OpenIPMI srvadmin-all
或者
yum install -y srvadmin-base srvadmin-storageservices 推荐,安装必要的软件,速度快
1234567891011121314151617181920 [root@BETA6 yum.repos.d]# yum -y install OpenIPMI srvadmin-all
[root@BETA6 yum.repos.d]# /opt/dell/srvadmin/sbin/srvadmin-services.sh start
[root@BETA6 yum.repos.d]# /etc/init.d/dataeng stop
[root@BETA6 yum.repos.d]# /etc/init.d/dataeng start
[root@BETA6 yum.repos.d]# chkconfig dataeng on
或者
[root@BETA6 yum.repos.d]# /opt/dell/srvadmin/sbin/srvadmin-services.sh enable 推荐
instsvcdrv 0:off 1:off 2:on 3:on 4:on 5:on 6:off
dataeng 0:off 1:off 2:on 3:on 4:on 5:on 6:off
dsm_om_shrsvc 0:off 1:off 2:on 3:on 4:on 5:on 6:off
ipmi 0:off 1:off 2:on 3:on 4:on 5:on 6:off
[root@BETA6 yum.repos.d]# /opt/dell/srvadmin/sbin/srvadmin-services.sh status
dell_rbu(module) is running
ipmidriver is running
dsm_sa_datamgrd(pid 1331 1197) is running
dsm_sa_eventmgrd(pid 1381) is running
dsm_sa_snmpd(pid 1440) is running
dsm_om_shrsvcd(pid 1508) is running...
dsm_om_connsvcd(pid 1562) is running...
[root@BETA6 yum.repos.d]# netstat -antlp|grep :1311
如果有此端口则说明我们的srvadmin安装成功,如果没有可能是安装出现问题了;dsm_om_connsvc服务监听了TCP协议的1311端口,并且提供了http访问的功能。另外我们安装完后首次启动用/opt/dell/srvadmin/sbin/srvadmin-services.sh start,否则用service dataeng start启动可能会有问题,导致omsa没有完全启动。dsm_om_connsvc服务监听了TCP协议的1311端口,并且提供了http访问的功能。
注意:
(1)一定要先安装snmp服务再安装omsa,这样omsa会自动将你的snmp服务进行配置,如果顺序颠倒则可能会导致报一下错误:
ERROR: (SNMP) OpenManage is not installed or is not working correctly
这是因为我们的/etc/snmp/snmpd.conf配置文件有漏改的地方,主要是以下几处:(改正以后如下)
view all included .1
view systemview included .1.3.6.1.2.1.1
view systemview included .1.3.6.1.2.1.25.1.1
access notConfigGroup ""any noauth exact all all none
(2)如果报一下错误“SNMP CRITICAL: No response from remote host 'X.X.X.X'”,则说明被监控端没有安装snmp服务
4、查看本机的硬件状态
1)查看系统主要组件的温度
[root@BETA6 yum.repos.d]# /opt/dell/srvadmin/bin/omreport chassis temps
Temperature Probes Information
------------------------------------
Main System Chassis Temperatures: Ok
------------------------------------
Index : 0
Status : Ok
Probe Name : System Board Inlet Temp
Reading : 27.0 C
Minimum Warning Threshold : 3.0 C
Maximum Warning Threshold : 42.0 C
Minimum Failure Threshold : -7.0 C
Maximum Failure Threshold : 47.0 C
......
2)查看虚拟硬盘的状态
[root@BETA6 yum.repos.d]# /opt/dell/srvadmin/bin/omreport storage vdisk controller=0
Virtual Disk 0 on Controller PERC H710 Mini (Embedded)
Controller PERC H710 Mini (Embedded)
ID : 0
Status : Ok
Name : Virtual Disk 0
State : Ready
Hot Spare Policy violated : Not Assigned
Encrypted : No
Layout : RAID-5
Size : 1,675.50 GB (1799054426112 bytes)
Device Name : /dev/sda
......
3)查看控制器(即RAID卡)的属性
[root@BETA6 yum.repos.d]# /opt/dell/srvadmin/bin/omreport storage controller
Controller PERC H710 Mini (Embedded)
Controllers
ID : 0
Status : Ok
Name : PERC H710 Mini
Slot ID : Embedded
State : Ready
Firmware Version : 21.2.0-0007
Latest Available Firmware Version : Not Applicable
Driver Version : 00.00.06.15-rh
Minimum Required Driver Version : Not Applicable
Storport Driver Version : Not Applicable
Minimum Required Storport Driver Version : Not Applicable
Number of Connectors : 2
Rebuild Rate : 30%
......
5、防火墙配置
由于我们使用的是SNMP来监控,因此我们需要在被监控端对nagios服务器开启snmp端口udp 161
/sbin/iptables -A INPUT -i em1 -p udp -s 10.10.5.89 --dport 161 -m comment --comment "nagios snmp" -j ACCEPT
--------------------------------------------------------------------------------
OMSA在Windows服务器上安装部署
访问戴尔技术支持的官方网站:http://www.dell.com/support/home/cn/zh/cnbsd1?c=cn&l=zh&s=bsdi,根据sn号查找驱动程序选项栏里统管理标签下下载对应的版本

具体安装过程参照此贴:http://zh.community.dell.com/techcenter/systems-management/w/wiki/559.omsawindows
Linux上Nagios安装配置初入门 http://www.linuxidc.com/Linux/2016-08/133870.htm
Nagios 监控 SNMP 温度计 http://www.linuxidc.com/Linux/2016-08/134461.htm
Nagios监控系统主机与服务配置 http://www.linuxidc.com/Linux/2017-02/140486.htm
Nagios邮件报警配置简述 http://www.linuxidc.com/Linux/2017-02/140834.htm
Nagios本机及其他主机监控安装部署详解 http://www.linuxidc.com/Linux/2017-03/141600.htm
Nagios 的详细介绍:请点这里
Nagios 的下载地址:请点这里
本文永久更新链接地址:http://www.linuxidc.com/Linux/2017-05/143829.htm